๐ Overview
The RSTRENG Calculator estimates the remaining strength of corroded pipes using industry-accepted methods (Original/Modified RSTRENG, ASME B31G, API 579). It converts all units and guides users on acceptance for continued operation or the need for further assessment.
๐งพ Inputs
- Pipe Outside Diameter: mm, inches (selectable)
- Wall Thickness: mm, inches (selectable)
- Maximum Defect Depth: mm, inches (selectable)
- Defect Length (axial): mm, inches (selectable)
- SMYS (Yield Strength): MPa, psi (selectable)
- Assessment Method:
- Original RSTRENG
- Modified RSTRENG
- ASME B31G
- API 579
- Output Pressure Unit: bar, psi, MPa
๐งฎ Calculations
- All inputs are converted to SI units for consistency.
- The calculation uses the Folias Factor and defect geometry for remaining strength: Pf=frac2S(tโd)DcdotFFP_f = \\frac{2 S (t-d)}{D \\cdot FF}Pfโ=frac2S(tโd)DcdotFF
- PfP_fPfโ: Failure pressure (MPa)
- SSS: SMYS (MPa)
- ttt: Wall thickness (mm)
- ddd: Defect depth (mm)
- DDD: Outside diameter (mm)
- FFFFFF: Folias factor (method-dependent)
- Acceptance is based on the minimum remaining wall ratio (method-dependent).
๐ค Outputs
- Acceptance Status: โ /โ ๏ธ (based on method and safety margins)
- Calculated Failure Pressure: user-selected units
- Folias Factor: (geometry influence)
- Defect/wall thickness ratio
- Summary of assessment method and logic