๐Ÿ“ Overview

The Slug Frequency Estimator predicts the rate of slug arrival (slug frequency) in multiphase pipelines. The tool accommodates different methods/codes and offers full unit flexibility for design and troubleshooting.


๐Ÿงพ Inputs

  • Pipeline Length: m, km, ft, mi (selectable)
  • Superficial Liquid Velocity: m/s, ft/s (selectable)
  • Slug Length: m, ft (selectable)
  • Applicable Method or Code:
    • API RP 14E
    • ISO 13623
    • DNVGL-RP-F110
    • Empirical/Field
  • Output Frequency Unit: slugs/hr, slugs/min, slugs/day

๐Ÿงฎ Calculations

  • Converts all input units to SI for calculations.
  • Slug frequency is calculated as: f=fracVsLsf = \\frac{V_s}{L_s}f=fracVsโ€‹Lsโ€‹ Where
    VsV_sVsโ€‹ = superficial liquid velocity
    LsL_sLsโ€‹ = slug length
  • For some codes/methods, additional safety or empirical factors may be included.
  • Flags โ€œAcceptableโ€ or โ€œHigh Frequency โ€“ Review Operationsโ€ based on code/method thresholds.

๐Ÿ“ค Outputs

  • Acceptance Status: โœ…/โš ๏ธ based on method/code guidance
  • Estimated Slug Frequency: In selected unit
  • Input Summary for transparency and traceability